Explore far better diagnostic data as a result of prolonged view from the anatomical composition on all convex probes.

iZoom™ permits accurate viewing of image from distance iWorks™ Protocol will help standardize workflow and lower Examination times

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi detail mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

Permits use of numerous scanned angles to sort just one image, causing Improved contrast resolution and improved visualization

The chapter provides the method to confirm primary operate and performance of product. This is certainly only used for reference, not preventive execution. Operate examining and tests of the part shall be carried out by Mindray company engineers as well as the user jointly. Site sixty six: General Exam

Usually do not use any cables aside from the cables offered Together with the system by Mindray. 3. Utilize the cable furnished with this system to connect the printer. Other cables may end in electric shock. Site 15: Mechanical Basic safety

Overall performance Exam 5.five.one Examination Course of action Resolution Detection depth Geometric Posture Accuracy Blackout place examination History the Test photographs five.5.2 Examination Content material The impression made use of here is only for reference, stay with the graphic impact in the actual Observe: problem. Requirements: Display: established the contrast and brightness on the clinical software price (or even the default status) Procedure natural environment: darkish space, simulating the medical application ecosystem. Site 76 In problem which the transverse resolution screening targets are horizontally displayed, file the minimum distance of two targets which can be clearly identified. Repeat the operation higher than to the transverse resolution testing targets at other depths. As demonstrated in determine under. Axial resolution ... Web page seventy seven When using the convex probe, retain the transverse resolution testing targets to NOTE: be exhibited near the midline. When utilizing a linear probe with steer perform, never turn on the steer purpose when carry out the transverse resolution exam. Zoom inside the location exactly where the targets Positioned if necessary. The diameter on the concentrate on stage at a particular depth is equivalent to the transverse resolution on the depth. Web site 78 5.

5.two.three Geometric positioning accuracy Longitudinal geometric positioning accuracy  Examination Action: Do changes as how in testing the maximum depth. History the distance by 20mm Every single section to the longitudinal targets line utilizing the measurement caliper; Find the worth with the best error (to 20mm), compute the accuracy using the formula below The measurement caliper needs to be positioned with the higher fringe of the concentrate on, Take note:... Web site seventy nine Transverse geometric positioning accuracy  Test Step: Cover the scan area with the phantom with drinking water or couple gel, Carefully Call the probe Using the scan area Change the depth, generating the transverse targets to get displayed during the picture. Adjust the main target position being posited beside the transverse targets (the normal isn't apparent) Alter parameters like acquire, TGC, earning each transverse targets being Evidently displayed. Site eighty five.five.two.4 Blackout Location Take a look at Step: Protect the scan area in the phantom with drinking water or few gel, Carefully contact the probe With all the scan floor Change the depth in a lessen value, and set the focus at the closest destination to the scan surface. Decrease the value of parameters like AP, Acquire until finally the qualifications sound just might be witnessed. Site eighty one: Program Update And Maintenance

Notice: Ahead of uploading the log, ensure that the ultrasound method has long been connected to community, usually, the procedure may well alert “could not connect with server” The server (smtp.

Just after replacing the CPU module, crucial file has to be created Yet again according to the new MAC handle and prepared into HDD on the equipment. Or else, the configuration purpose of your product or service is going to be lost. Soon after getting rid of the CPU module, Eliminate panhead screws with washers (12 M3X6) fixed on the most crucial unit box, you usually takes from the board. Website page 118 Determine eight-29 Disassemble the User interface Assembly (one) Hold the upper edge of user interface assembly, and open up up the control panel. Determine eight-30 Disassemble the User interface Assembly (two) Just after eliminating 1 countersunk head self-tapping screw PT3X10 mounted on the control panel and take out the plug from the Dp50rb login keyboard and the key unit connecting cables, you can get rid of the control panel assembly.

Once you cease the scanning and also the impression seize, it is best to energy off the technique and disconnect the procedure from the AC electrical power offer, then pull out AC energy cables. Site 109: Battery Connecting Board

This guide may possibly referring to details protected by copyright or patents and isn't going to Express any license under the patent rights or copyright of Mindray, or of Other individuals. Web page nine: Statement

Reduce off cable ties connecting the principle device over the display by diagonal cutting pliers, then pull out the corresponding cable plugs.

Observe: To the watch, the brightness adjustment arrives just before contrast. After readjusting the monitor’s distinction and brightness, alter all preset and peripheral settings.